Performance Grade (PG) bitumen undergoes grading based on its performance under various temperatures, a method designed by the Long-Term Pavement Performance (LTPP). This approach determines the highest and lowest pavement temperatures and selects bitumen performing well within that range.
Penetration and viscosity grading, while common, possess limitations in fully characterizing asphalt binder for Hot Mix Asphalt (HMA) pavement. To address this, the Superpave research initiative developed new tests and specifications aiming to more accurately characterize asphalt binders, considering parameters such as rutting, fatigue, and thermal cracking in HMA pavements.
The Superpave Performance Grading (PG) system correlates asphalt binder properties with specific usage conditions, accounting for expected climate and aging effects. It utilizes a battery of tests, specifying the temperatures at which binders must pass, tailored to the prevailing climatic conditions. This system offers more precise relationships between asphalt properties and field conditions compared to traditional grading methods.
How to read a PG Grade?
Specification of Performance Grade(PG) Bitumen – Unmodified
|
PG 46-34
|
PG 46-28
|
PG 52-28
|
PG 58-28
|
PG 58-22
|
PG 64-22
|
AASHTO Method
|
|
|---|---|---|---|---|---|---|---|
| Original Binder | |||||||
| Flash Point, COC,°C |
230
|
T 48 | |||||
| Flash Point, P-M, °C |
NS
|
≥ 204
|
ASTM D93 | ||||
| Rotational Viscosity @ 135°C, Pa·s |
3.00
|
T 316 | |||||
| Dynamic Shear @ Grade Temperature,°C |
46
|
46
|
52
|
58
|
58
|
64
|
T 315 |
| G*/sin @ 10 rad/sec, kPa |
≥ 1.00
|
||||||
| RTFOT Residue | |||||||
| Mass Loss, % |
≤ 1.00
|
T 240 | |||||
| Dynamic Shear @ Grade Temperature,°C |
46
|
46
|
52
|
58
|
58
|
64
|
T 315 |
| G*/sin @ 10 rad/sec, kPa |
2.20
|
||||||
| PAV Residue (Aging Temperature, °C) |
90
|
100
|
R 28 | ||||
| Dynamic Shear @ Grade Temperature,°C |
10
|
13
|
16
|
19
|
22
|
25
|
T 315 |
| G*/sin @ 10 rad/sec, kPa |
5000
|
||||||
| Creep Stiffness |
-24
|
-18
|
-18
|
-18
|
-12
|
-12
|
|
| S, Mpa |
≤ 300
|
T 313 | |||||
| m-value |
≥ 0.30
|
T 313 | |||||